Tripp Lite Monitored PDU 30A16 Outlets 5 15 20R 120V L5 30P 10 FT PDUMNH30
$ 158.4
- Description
- Size Guide
Description
Tripp Lite Monitored PDU, 30A, 16 Outlets (5-15/20R), 120V, L5-30P, 10 ft. Cord, 2U Rack-Mount Power (PDUMNH30)Dont Pay over 0 for a brand new one!!! AND especially dont trust a "refurbished" one!
This one works great! Check out the pictures!
Get a GREAT DEAL!!!
Comes with rack ears to mount into a rack, plug it in and it's ready to go!
More detailed tech specs below.
Monitored PDUMNH30 horizontal 2U monitored rack PDU supports 30A maximum capacity at 120V (agency de-rated to 24A/2.88kW continuous). Includes 10feet/3m attached line cord with L5-30P input plug and 16 5-15/20R outlets. Outlets are arranged in two separately brokered 8 outlet load banks. Visual and remote current monitoring tracks total output load in amps, plus output current levels for each output load bank. Supports 2U horizontal rackmount installation with included mounting brackets. Included cord retention plates keep vital network equipment plugged in and continuously powered. Monitored PDU systems support real-time remote monitoring via secure web, SNMP or Telnet interface and custom notification of user-specified remote conditions via email and SNMP trap. PDU power consumption in amps is displayed locally via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers become overloaded. Advanced configurations support in-rack environmental monitoring with optional ENVIROSENSE temperature/humidity probe and rack access notification for up to 4 SRSWITCH or user supplied contact-closure sensors. Supports real-time monitoring of all reported functions with support for user- specified alarm and notification thresholds. Fully compatible with Power Alert Network Management System Software. From the Manufacturer Do you need an efficient way to distribute and monitor power in an IT or industrial environment? Tripp Lite's PDUMNH30 Monitored Power Distribution Unit is the solution you seek! Featuring a built-in SNMPWEBCARD, the PDUMNH30 provides full remote power monitoring via a secure network or web browser interface. Used with an optional environmental sensor module (Tripp Lite model ENVIROSENSE), the PDUMNH30 can also provide temperature/humidity, magnetic door switch and dry contact interface monitoring. These capabilities provide IT personnel with enhanced oversight of facility power and environmental conditions. The PDUMNH30 is configurable for 2U rackmount installation with included hardware. Key Features Advanced Network Monitoring CapabilitiesClick here for a larger image Network Interface, Cicuit Breakers and Digital Current MeterClick here for a larger image Advanced Network Monitoring Capabilities The PDUMNH30 gives IT personnel enhanced oversight of network power conditions. It remotely monitors site power conditions and PDU load levels, and supports notification and logging of all major power events and user- specified alarm thresholds via email or SNMP traps. Real-time clock backup maintains the time of day and date even if the PDU is shut down and unpowered. Used with Tripp Lite's optional ENVIROSENSE sensor, the PDUMNH30 can also remotely monitor temperature/humidity conditions plus up to four Tripp Lite SRSWITCH magnetic door switches or dry contact interfaces for alarm, security and telecom devices. These capabilities simplify and streamline the task of network power management. Built-In Network Interface with Broad Compatibility The PDUMNH30 features a built-in SNMPWEBCARD that enables full remote power monitoring via a secure network or web browser interface. The PDUMNH30 provides 10/100 Mbps auto-sensing for optimal communication compatibility with a 10/100 Base-T network. Protocols supported include, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, Telnet, FTP, DHCP, BOOTP and NTP. DHCP/Manual configuration support provides the ability to have network settings automatically assigned to the card, or manually assigned via permanent IP addresses. Sequentially Activated Outlets The PDUMNH30's sixteen 5-15/20R outlets are arranged in two eight-outlet load banks, each with its own 20A circuit breaker. To prevent inrush-related equipment interaction at startup, the outlets are factory-programmed for sequential activation at 250-millisecond intervals when the PDUMNH30 is energized. Digital Current Meter The PDUMNH30 is equipped with a digital LED meter that enables IT personnel to monitor the load on the PDU at the rack in real time. This meter helps to assure that the PDU is used at maximum capacity with no danger of overload. A toggle switch enables the meter to display the load on either eight-outlet load bank or the total load on the PDU. Optimized for Demanding Applications The PDUMNH30 is designed for reliable distribution of AC power to supported equipment in IT, industrial and similar applications. It features a rugged all-metal case, high-quality outlets, a 20A circuit breaker and a switchless design with included cord retention brackets to prevent accidental shutoff. The PDUMNH30 can be configured for 2U rackmount installation with included hardware, making it easy to integrate with a wide range of data center and network applications. Technical Specifications Tripp Lite PDUMNH30 Monitored Power Distribution Unit Click here for a larger image What's in the Box PDUMNH30 Switched/Metered PDU Mounting Hardware Cord Retention Brackets SNMPWEBCARD Configuration Cable Protect, Power, Organize and Control with Tripp Lite Tripp Lite UPS Systems and accessories are available with a wide range of features to provide reliable, cost-effective power protection and connectivity solutions for all electronics. PDUMNV30 Monitored Power Distribution Unit Monitored 0U (vertical) rackmount PDU with 24 x 5-15/20R outlets arranged in two separately breakered 12-outlet load banks and 10-ft. cord with L5-30P plug. The PDUMV30NET provides 30A 120V capacity, remote power monitoring via a secure web/network interface, a digital amp meter for on-site monitoring of total PDU load, and sequential outlet power-on capability to prevent inrush-related equipment interaction on startup. Switchless design prevents accidental shut-off. Supports toolless button-mount vertical installation in all Tripp Lite and other compatible rack enclosures. 2-year warranty. PDUMH30NET Switched/Metered Power Distribution Unit Switched/metered 2U rackmount PDU with 16 x 5-15/20R outlets arranged in two separately breakered 8-outlet load banks and 10-ft. cord with L5-30P plug. The PDUMH30NET provides 30A 120V capacity, remote power management and individual outlet control via a secure web/network interface, digital amp meter for on-site monitoring of total PDU load, and sequential outlet power-on capability to prevent inrush-related equipment interaction on startup. Switchless design prevents accidental shut-off. 2-year warranty. SU3000RTXL3U™ UPS System True on-line operation with pure sine wave output and zero transfer time provides the highest level of protection for mission-critical equipment. The SU3000RTXL3U provides 3000VA/2400W power capacity with 9 outlets arranged in 2 load banks. One USB port and one DB9 port with included cables and PowerAlert monitoring software provide complete power network monitoring and control. The SU3000RTXL3U supports connected equipment for 14 minutes during power failures at a half load of 1200 watts and runtime is expandable with optional external battery packs. 0,000 Ultimate Lifetime Insurance; 2-year warranty. SRCOOL12K Self-Contained Portable Air Conditioning Unit Compact, portable air conditioning unit is ideal for wiring closets and other space- critical locations where facility air conditioning can't reach. 12,000 BTU of cooling power. Connects to a standard 5-15R receptacle; no adapter required. Uses EPA-compliant, R410a refrigerant. Standard louvered vent for general room cooling; ducted vent to direct cold air where needed. Requires no floor drain or water collection tank. 1-year warranty. B020-U16-19-K NetDirector™ Console KVM Switch Controls an entire network in just 1U of rack space. The B020-U16-19-K combines a keyboard, 19-in. LCD screen, touch pad, numeric keypad, and 16-port KVM switch in a 1U slide-out unit. It is USB or PS/2 compatible with 8 included PS2/USB Combo Cable Kits for connection to servers. Controls up to 512 servers by daisy-chaining additional KVMs. Includes two front-mounted USB ports: one for attachment of a separate USB mouse and one to connect USB peripherals (flash drive, external hard drive, etc.) that can be shared between connected servers. SR42UB SmartRack™ Enclosure Premium 42U rack enclosure organizes and secures all standard rackmount equipment. The SR42UB features locking, removable, reversible front and rear doors; locking, removable side panels keyed alike with doors; 4 interior vertical posts with unthreaded square-hole openings; preinstalled casters and leveling feet; and 3000-lb. stationary/2250-lb. rolling load capacity. The SR42UB ships fully assembled and comes with a 5-year repair/replacement warranty. A full range of rackmount accessories is also available.
Features:
120V 30A Monitored Power Distribution Unit (PDU) with built-in web/network interface in 2U rackmount form factor
L5-30P 30A 120V input plug and 16 NEMA 5-15/20R output receptacles
30A maximum capacity (Agency derated to 24A continuous)
Outlets are arranged in two separately brokered 8 outlet loading banks
Supports local current metering and network monitoring via built-in web/network monitoring and control card
For any additional questions on features, please contact us
Product Details:
Product Dimensions: 12.5 x 17.5 x 3.5 inches
Item Weight: 13.89 pounds
Shipping Weight: 16.05 pounds
Item model number: PDUMNH30